Skip to main content

mcr Silboard

  • Advanced fire protection technology
    Calcium silicate board with exceptional fire resistance and non-combustibility.
  • For all types of buildings
    An ideal solution for securing smart buildings and OEM facilities.
  • For public utility buildings
    Perfect for schools, hospitals, offices, and other public facilities.
  • For industry and infrastructure
    Excellent for production halls, warehouses, and industrial facilities.

Do you need such a solution?

mcr Silboard

Technologically advanced, fire-resistant calcium silicate board.

Thanks to its physical and mechanical properties, including non-combustibility, mcr Silboard can be used for fire protection of all types of buildings.

Application

Installation ducts

  • for building self-supporting ventilation and smoke extraction ducts, cable ducts, and installation shafts
  • ensuring continuity of power supply or signal transmission for up to 120 minutes

Construction protection

  • Perfect for protecting reinforced concrete structures strengthened with carbon fibre, as well as for steel structures in single- or double-layer systems.

Building elements

  • Used in the construction of non-load-bearing fire-separation walls and for building suspended ceilings.

Characteristics

This high mechanical strength material is easy to process, allowing quick, simple, and clean installation.

The product is non-toxic, contains no substances harmful to health, and is resistant to biological corrosion such as fungi and bacteria.

Technical specification

Available thicknesses
20 mm, 30 mm, 35 mm, 40 mm, 50 mm
Sizes
2500x 1200 mm, 2400x 1200 mm 1250x 800 mm, 1150x 800 mm
Appearance
White/cream, one side finely ground smooth
Density
550 ± 15% kg/m³
Compressive strength
≥1.0 MPa
Tensile strength perpendicular to surface
≥0.10 MPa
Tensile strength parallel to surface
≥0.40 MPa
Dimensional stability
Dimensionally stable boards
Thermal conductivity
0.095 W/(m·K)
Reaction to fire class
A1
Service category
Y

Request a quote